One region, stretched across two sites
Full name: Multiple Sites in a Single Region
Two datacentres in the same metro running as availability zones, with stretched vSAN and NSX segments. Storage is replicated synchronously, so losing one zone loses no data. The lost zone's virtual machines restart automatically in the surviving zone, and their service stops until the restart completes.
The drawing as a list: its 6 parts
- fleet-01Fleet · VCF Operations · VCF Automation · Identity Broker
- instance-aVCF instance · AZ1 + AZ2 · High Availability Small
- mgmt-aManagement domain · NSX ×3
- mgmt-a-cl01vSphere cluster · 4 + 4 hosts · vSAN ESA · stretched
- wld-prodVI workload domain · NSX ×3
- wld-prod-cl01vSphere cluster · 3 + 3 hosts · vSAN ESA · stretched
- mgmt-aManagement domain · NSX ×3
- instance-aVCF instance · AZ1 + AZ2 · High Availability Small
Sites, zones and regions
Key facts
Enterprise use cases
- Core banking and paymentsRecover ledgers and payment switches in the surviving datacentre after a datacentre failure, with no data lost and a restart of their virtual machines.
- Electronic health recordsClinical systems that cannot lose a transaction if one datacentre fails.
- Trading and treasuryLatency-sensitive platforms that need site resilience inside one metro.
- Digital channelsMobile and web front ends with no data loss between availability zones.
Industry verticals
Examples of where it fits. Your own recovery, availability and data residency requirements decide.
- Banking and FSICore banking, payments and cards
- InsurancePolicy administration and claims
- HealthcareEHR and clinical systems
- TelcoBSS, OSS and customer care
- Public sectorCitizen-facing digital services
Typical add-ons
- vDefend
- Avi Load Balancer
- VCF Operations
- Protection and Recovery
Checks on the starter design
5 checks need input17 of 23 checks pass on the starter design as it is. 5 need input: the design is missing facts they check, and 1 is a note. These checks and their sources are listed below. Open the design on the canvas to change it.
The 5 checks that need input and 1 note, each with its source
- NEEDS INPUTmgmt-a-cl01 · Inter-site latency for stretched vSAN: not checked yet. Add the round-trip time between data sites to the design to check it. Evidence: rule verifiedSource: Stretched vSphere Cluster Model
What the source says
When using vSAN stretched clusters, the bandwidth between the zones must be at least 10 Gbps and the round-trip latency must be less than 5 ms.
Also: "When using vSAN stretched clusters, a third independent fault domain is required to host the vSAN witness appliance." "Having the management domain on a stretched cluster is a prerequisite to configure and implement stretched cluster in a workload domain." "If you add more ESX hosts to the default management vSphere cluster, add them in pairs, one per availability zone." Its host minimum table gives the first management domain cluster on stretched vSAN six hosts for Simple and eight for High Availability.Stretched vSphere Cluster Model
- NEEDS INPUTwld-prod-cl01 · Inter-site latency for stretched vSAN: not checked yet. Add the round-trip time between data sites to the design to check it. Evidence: rule verifiedSource: Stretched vSphere Cluster Model
What the source says
When using vSAN stretched clusters, the bandwidth between the zones must be at least 10 Gbps and the round-trip latency must be less than 5 ms.
Also: "When using vSAN stretched clusters, a third independent fault domain is required to host the vSAN witness appliance." "Having the management domain on a stretched cluster is a prerequisite to configure and implement stretched cluster in a workload domain." "If you add more ESX hosts to the default management vSphere cluster, add them in pairs, one per availability zone." Its host minimum table gives the first management domain cluster on stretched vSAN six hosts for Simple and eight for High Availability.Stretched vSphere Cluster Model
- NEEDS INPUTinstance-a VCF Management Services · VCF Management Services IP addresses: not checked yet. Add the number of IP addresses set aside for VCF Management Services to the design to check it. Evidence: rule verifiedSources: Deploy VCF Management Services and License Server as Part of VCF Upgrade to 9.1 · First VCF Instance FQDNs and IP addresses
What the sources say
A minimum of 12 IP addresses are required for deployment (/28 CIDR block).
Also: "The IP addresses can be contiguous or non-contiguous."Deploy VCF Management Services and License Server as Part of VCF Upgrade to 9.1VCF services runtime nodes *** Minimum: 12 IP addresses are required for deployment.
First VCF Instance FQDNs and IP addresses
- NEEDS INPUTVCF Automation · VCF Automation IP addresses: not checked yet. Add the size of the VCF Automation IP pool to the design to check it. Evidence: rule verifiedSources: Deploying VCF Automation as a Day-N Operation, IP addresses · VCF Installer Deployment Wizard, VCF Automation IP addresses
What the sources say
Because a /29 CIDR block provides eight IP addresses and VCF Automation requires five IP addresses, three addresses are free.
Deploying VCF Automation as a Day-N Operation, IP addressesFor deployments version 9.1.0.400 and later, you specify 5 IP addresses as contiguous or non-contiguous IP range.
VCF Installer Deployment Wizard, VCF Automation IP addresses
- NEEDS INPUTVCF Automation · Host size for the VCF Automation appliance: not checked yet. Add the cores per host in the management domain to the design to check it. Evidence: rule from a single sourceSources: Adrian Heissler: VCF Automation 9.1 anatomy · VCF 9.1.1 Planning and Preparation Workbook: VCF Automation tables (Static Reference Tables sheet) · VCF Taxonomy, where the fleet components run
What the sources say
- Not a techdocs page. It is kept only for the rule that the VCF Automation appliance needs a host with at least 12 cores and 24 threads, which neither the 9.1 techdocs pages nor the workbook state. The appliance size comes from the workbook's VCF Automation tables.Adrian Heissler: VCF Automation 9.1 anatomy
VCF Automation CPU Value Small 24 Medium 24 Large 32
Hidden sheet, quoted as table cells run together. Also: "VCF Automation RAM Value Small 96 Medium 96 Large 128", "VCF Automation Disk Value Small 600 Medium 900 Large 1200".VCF 9.1.1 Planning and Preparation Workbook: VCF Automation tables (Static Reference Tables sheet)A VCF fleet contains one or more VCF Instances and might contain one or more standalone vCenter instances, managed by the VCF Operations instance for the fleet. The components of the VCF fleet are running in the management domain of the first VCF Instance.
VCF Taxonomy, where the fleet components run
- NOTEwld-prod · In 9.1 creating a VI workload domain creates a new vCenter Single Sign-On domain, isolated from the other workload domains in the VCF instance. Evidence: verifiedSource: Create a New Workload Domain
What the source says
SSO Domain Name Enter the vCenter Single Sign-On (SSO) domain name, for example, example.domain.local . This creates a workload domain that is isolated from the other workload domains in your VCF instance.
The wizard asks: "Enter the vCenter Single Sign-On (SSO) domain name, for example, example.domain.local".Create a New Workload Domain
Sources
- [1] Design Blueprints for VMware Cloud Foundation
- [2] VCF Fleet with Multiple Sites in a Single Region
- [3] Stretched vSphere Cluster Model
- [4] Stretched vSAN Storage Model, in VCF Fleet with Multiple Sites in a Single Region
- [5] VCF Fleet Deployment Models
The use cases, industries and add-ons are judgement calls about typical fit, not Broadcom guidance.
- Drawing
- BP-03
- Title
- Multiple Sites in a Single Region
- Release
- VCF 9.1.1
- Layout
- 1 instance · 2 domains
- Scale
- NTS
- Checked
- 5 checks need input